DESCRIPTION
PENETRON ADMIX® (integral crystalline waterproofing admix) is added to the concrete mix at the
time of batching. PENETRON ADMIX® consists of
Portland cement and various active, proprietary
chemicals. These active chemicals react with the
moisture in fresh concrete and with the by-products
of cement hydration to cause a catalytic reaction,
which generates a non-soluble crystalline formation
throughout the pores and capillary tracts of the
concrete. Thus, the concrete becomes permanently
sealed against the penetration of water or liquids from
any direction. The concrete is also protected from
deterioration due to harsh environmental conditions.
PENETRON ADMIX® has been specially formulated
to meet varying project and temperature conditions
(see Setting time and strength). Consult with a Penetron technical representative for additional detailed
support on your project.
APPLICATIONS
Reservoirs
Sewage and water treatment plants
Secondary containment structures
Tunnels and subway systems
Underground vaults
Foundations
Parking structures
Swimming pools
Precast, cast-in-place and shotcrete applications
ADVANTAGES
Resists extreme hydrostatic pressure from either
positive or negative surface of the concrete slab
Becomes an integral part of the concrete
Highly resistant to aggressive chemicals
Can seal hairline cracks up to 1/51” (0.5 mm)
Allows concrete to breathe
Non-toxic (NSF 61 certified for potable water applications)
Less expensive than traditional methods
Permanent
Added to the concrete at the time of batching and
therefore not subject to climatic restraints
Reduces construction scheduling time
Improves durability of concrete
Permeability Reducing Admixture for Hydrostatic
conditions (PRAH)
Zero VOC – PENETRON powdered products contain
zero volatile organic compounds and are safe for use
both outdoors and in confined indoor spaces
Exceeds requirements of ASTM C494-S (Specific
Performance Admixtures)

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select Link to start with 

1. Liquid: PENETRON ADMIX® LIQUID must be added to the concrete at the time of batching. PENETRON ADMIX® LIQUID should be introduced into the concrete with the initial batch water. PENETRON ADMIX® LIQUID replaces the equivalent volume of mix water. Setting time and strength: The setting time of concrete is affected by the chemical and physical composition of ingredients, temperature of the concrete and climatic conditions. Retardation of set may occur when using PENETRON ADMIX®. The amount of retardation will depend upon the concrete mix design and the dosage rate of PENETRON ADMIX®. However, under normal conditions, PENETRON ADMIX® will provide a normal set concrete. Concrete containing PENETRON ADMIX® may develop higher ultimate strengths than plain concrete. Trial mixes should be carried out under project conditions to determine setting time and strength of the concrete. Concrete treated with PENETRON ADMIX® should be placed and finished in accordance with good concrete practices. ACI guidelines and recommendations should be observed. SPECIAL CONSIDERATIONS When incorporating PENETRON ADMIX®, the temperature of the concrete mix should be above 40ºF (4ºC). PACKAGING Powder: PENETRON ADMIX® is available in 40-lb (18-kg) bags, 55-lb (25-kg) pails, and 6.6-lb (3-kg) soluble bags. For large projects, customized packaging is available. Liquid: PENETRON ADMIX® LIQUID is available in 264-gallon (1000-l) and 275-gallon (1041-l) totes. STORAGE / SHELF LIFE Powder: PENETRON products must be stored dry at a minimum temperature of 45ºF (7ºC). Shelf life is 24 months when stored under proper conditions. Liquid: PENETRON products must be stored at a minimum temperature of 45ºF (7ºC). Shelf life is 24 months when stored under proper conditions. Agitate periodically if storing for an extended period of time. DO NOT ALLOW TO FREEZE! TECHNICAL SERVICES For more detailed instructions, alternative application methods, or informa - tion concerning the compatibility of the PENETRON treatment with other products or technologies, contact the Penetron Technical Department or your local Penetron representative. SAFE HANDLING INFORMATION PENETRON ADMIX® is alkaline. As a cementitious powder, liquid or mixture, PENETRON ADMIX® may cause significant skin and eye irritation. Penetron International, Ltd. also maintains comprehensive and up-to-date Safety Data Sheets on all its products. Each sheet contains health and safety information for the protection of your employees and customers. KEEP OUT OF REACH OF CHILDREN. Contact Penetron International, Ltd. or your local Penetron representative to obtain copies of Safety Data Sheets prior to product storage or use. PENETRON ADMIX ® DIRECTIONS FOR USE Dosage rate: Powder: 0.8-1.0% by weight of cement. Consult with Penetron’s Technical Department for assistance in verifying the appropriate dosage rate and for further information regarding enhanced chemical resistance and optimum concrete performance for your project. Liquid: Add 16 ounces of PENETRON ADMIX® LIQUID for every 100 lb of cementing materials (1.0 l of PENETRON ADMIX® LIQUID for every 100 kg of cementing materials). Consult with Penetron’s Technical Department for further information regarding enhanced chemical resistance and optimum concrete performance for your project. Mixing: Powder: PENETRON ADMIX® Powder must be added to the concrete at the time of batching. The sequence of procedures for addition will vary according to the type of batch plant operation and equipment. The following are some typical mixing guidelines. For more detailed information on dosing procedures, contact your Penetron representative. Ready mix plant - Dry batch operation: Add PENETRON ADMIX® in powder form to the drum of the ready-mix truck. Drive the truck under the batch plant and add 60%-70% of the required water, along with 300-500 lb (136-227 kg) of aggregate. Mix the materials for 2-3 minutes to ensure the PENETRON ADMIX® is distributed evenly throughout the mix water. Add the balance of materials to the ready-mix truck in accordance with standard batching practices. Ready mix plant - Central mix operation: Mix PENETRON ADMIX® with water to form a very thin slurry (e.g. 40 lb (18 kg) of powder mixed with 6 gallons (22.7 l) of water). Pour the required amount of material into the drum of the ready-mix truck. The aggregate, cement, sand and water should be batched and mixed in the plant in accordance with standard practices (taking into account the quantity of water that has already been placed in the ready-mix truck). Pour the concrete into the truck and mix for at least 5 minutes to ensure even distribution of PENETRON ADMIX® throughout the concrete. Precast batch plant: Add PENETRON ADMIX® in powder form, to the rock and sand, then mix thoroughly for 2-3 minutes before adding the cement and water. The total concrete mass should be blended using standard practices. NOTE: It is important to obtain a homogeneous mixture of PENETRON ADMIX® with the concrete. Therefore, do not add dry PENETRON ADMIX® powder directly to wet concrete as this may cause clumping, and thorough dispersion will not occur. For further information regarding the proper use of PENETRON ADMIX® for a specific project, consult with a Penetron technical representative. TOTAL CONCRETE PROTECTION ® DESCRIPTION PENETRON ADMIX® (integral crystalline water - proofing admix) is added to the concrete mix at the time of batching. PENETRON ADMIX® consists of Portland cement and various active, proprietary chemicals. These active chemicals react with the moisture in fresh concrete and with the by-products of cement hydration to cause a catalytic reaction, which generates a non-soluble crystalline formation throughout the pores and capillary tracts of the concrete. Thus, the concrete becomes permanently sealed against the penetration of water or liquids from any direction. The concrete is also protected from deterioration due to harsh environmental conditions. PENETRON ADMIX® has been specially formulated to meet varying project and temperature conditions (see Setting time and strength ). Consult with a Pene - tron technical representative for additional detailed support on your project. APPLICATIONS Reservoirs Sewage and water treatment plants Secondary containment structures Tunnels and subway systems Underground vaults Foundations Parking structures Swimming pools Precast, cast-in-place and shotcrete applications ADVANTAGES Resists extreme hydrostatic pressure from either positive or negative surface of the concrete slab Becomes an integral part of the concrete Highly resistant to aggressive chemicals Can seal hairline cracks up to 1/51” (0.5 mm) Allows concrete to breathe Non-toxic (NSF 61 certified for potable water applications) Less expensive than traditional methods Permanent Added to the concrete at the time of batching and therefore not subject to climatic restraints Reduces construction scheduling time Improves durability of concrete Permeability Reducing Admixture for Hydrostatic conditions (PRAH) Zero VOC – PENETRON powdered products contain zero volatile organic compounds and are safe for use both outdoors and in confined indoor spaces Exceeds requirements of ASTM C494-S (Specific Performance Admixtures) ® CRYSTALLINE WATERPROOFING ADMIXTURE Page 1

2. Liquid: PENETRON ADMIX® LIQUID must be added to the concrete at the time of batching. PENETRON ADMIX® LIQUID should be introduced into the concrete with the initial batch water. PENETRON ADMIX® LIQUID replaces the equivalent volume of mix water. Setting time and strength: The setting time of concrete is affected by the chemical and physical composition of ingredients, temperature of the concrete and climatic conditions. Retardation of set may occur when using PENETRON ADMIX®. The amount of retardation will depend upon the concrete mix design and the dosage rate of PENETRON ADMIX®. However, under normal conditions, PENETRON ADMIX® will provide a normal set concrete. Concrete containing PENETRON ADMIX® may develop higher ultimate strengths than plain concrete. Trial mixes should be carried out under project conditions to determine setting time and strength of the concrete. Concrete treated with PENETRON ADMIX® should be placed and finished in accordance with good concrete practices. ACI guidelines and recommendations should be observed. SPECIAL CONSIDERATIONS When incorporating PENETRON ADMIX®, the temperature of the concrete mix should be above 40ºF (4ºC). PACKAGING Powder: PENETRON ADMIX® is available in 40-lb (18-kg) bags, 55-lb (25-kg) pails, and 6.6-lb (3-kg) soluble bags. For large projects, customized packaging is available. Liquid: PENETRON ADMIX® LIQUID is available in 264-gallon (1000-l) and 275-gallon (1041-l) totes. STORAGE / SHELF LIFE Powder: PENETRON products must be stored dry at a minimum temperature of 45ºF (7ºC). Shelf life is 24 months when stored under proper conditions. Liquid: PENETRON products must be stored at a minimum temperature of 45ºF (7ºC). Shelf life is 24 months when stored under proper conditions. Agitate periodically if storing for an extended period of time. DO NOT ALLOW TO FREEZE! TECHNICAL SERVICES For more detailed instructions, alternative application methods, or informa - tion concerning the compatibility of the PENETRON treatment with other products or technologies, contact the Penetron Technical Department or your local Penetron representative. SAFE HANDLING INFORMATION PENETRON ADMIX® is alkaline. As a cementitious powder, liquid or mixture, PENETRON ADMIX® may cause significant skin and eye irritation. Penetron International, Ltd. also maintains comprehensive and up-to-date Safety Data Sheets on all its products. Each sheet contains health and safety information for the protection of your employees and customers. KEEP OUT OF REACH OF CHILDREN. Contact Penetron International, Ltd. or your local Penetron representative to obtain copies of Safety Data Sheets prior to product storage or use. PENETRON ADMIX ® DIRECTIONS FOR USE Dosage rate: Powder: 0.8-1.0% by weight of cement. Consult with Penetron’s Technical Department for assistance in verifying the appropriate dosage rate and for further information regarding enhanced chemical resistance and optimum concrete performance for your project. Liquid: Add 16 ounces of PENETRON ADMIX® LIQUID for every 100 lb of cementing materials (1.0 l of PENETRON ADMIX® LIQUID for every 100 kg of cementing materials). Consult with Penetron’s Technical Department for further information regarding enhanced chemical resistance and optimum concrete performance for your project. Mixing: Powder: PENETRON ADMIX® Powder must be added to the concrete at the time of batching. The sequence of procedures for addition will vary according to the type of batch plant operation and equipment. The following are some typical mixing guidelines. For more detailed information on dosing procedures, contact your Penetron representative. Ready mix plant - Dry batch operation: Add PENETRON ADMIX® in powder form to the drum of the ready-mix truck. Drive the truck under the batch plant and add 60%-70% of the required water, along with 300-500 lb (136-227 kg) of aggregate. Mix the materials for 2-3 minutes to ensure the PENETRON ADMIX® is distributed evenly throughout the mix water. Add the balance of materials to the ready-mix truck in accordance with standard batching practices. Ready mix plant - Central mix operation: Mix PENETRON ADMIX® with water to form a very thin slurry (e.g. 40 lb (18 kg) of powder mixed with 6 gallons (22.7 l) of water). Pour the required amount of material into the drum of the ready-mix truck. The aggregate, cement, sand and water should be batched and mixed in the plant in accordance with standard practices (taking into account the quantity of water that has already been placed in the ready-mix truck). Pour the concrete into the truck and mix for at least 5 minutes to ensure even distribution of PENETRON ADMIX® throughout the concrete. Precast batch plant: Add PENETRON ADMIX® in powder form, to the rock and sand, then mix thoroughly for 2-3 minutes before adding the cement and water. The total concrete mass should be blended using standard practices. NOTE: It is important to obtain a homogeneous mixture of PENETRON ADMIX® with the concrete. Therefore, do not add dry PENETRON ADMIX® powder directly to wet concrete as this may cause clumping, and thorough dispersion will not occur. For further information regarding the proper use of PENETRON ADMIX® for a specific project, consult with a Penetron technical representative. 004aCPR2013-07-10 EN 934-2 Penetron International, Ltd. 601 South Tenth Street, Unit 300 Allentown, PA 18103 08 PENETRON ADMIX Crystalline Capillary Admixture Water Resisting Admixture Chloride content: < 0,10 % by mass Alkali content: < 10,3 % by mass Compressive strength: ≥ 85 % of control Conventional dry material content: > 99,5 % Air content in fresh concrete: ≤ 2 % by volume Capillary Absorption (after 90 day curing): ≤ 60 % by mass TOTAL CONCRETE PROTECTION ® Page 2 v. L10 45 Research Way, Suite 203, East Setauket, NY 11733 (631) 941-9700 • info@penetron.com • penetron.com PENETRON INTERNATIONAL, LTD. WARRANTY: PENETRON INTERNATIONAL, LTD. warrants that the products manufac - tured by it shall be free from material defects and will conform to formulation standards and contain all components in their proper proportion. Should any of the products be proven defective, the liability to PENETRON INTERNATIONAL, LTD. shall be limited to replacement of the material proven to be defective, and PENETRON INTERNATIONAL, LTD. shall in no case be liable otherwise or for incidental or consequential damages. PENETRON INTERNATIONAL, LTD. MAKES NO WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. User shall determine the suitability of the product for its intended use and assume all risks and liability in connection therewith.

Views

  • 2833 Total Views
  • 2149 Website Views
  • 684 Embeded Views

Actions

  • 0 Social Shares
  • 3
  • 0
  • 0 Comments

Share count

  • 0  Facebook
  • 0  Twitter
  • 0  LinkedIn

Embeds 4

  • 13 www.sab-us.com
  • 1 sab--us-com.translate.goog
  • 14 161.97.92.48
  • 4 161.97.92.48:8011

Website Visitors - 488312