RAKAM 112-RAK BLOCK FIX

Public Channel / Data Sheets

Adhesive for Autoclaved Aerated Concrete Block

112 - RAK BLOCK FIX is a powder adhesive composed of hydraulic binders, bonding
agents, quartz, synthetic resins and special additives formulated to obtain, when mixed
with water, optimal characteristics of workability and high adhesion power to the support.
It contains neither asbestos fibre nor other materials considered harmful for health of the
applicator.

Advantages:

• Factory controlled pre-blend ensures
consistent high quality
• Requires only addition of wa ter on site at
the time of usage
• Strong adhesion to AAC Blocks
• Mineral based non-hazardous
Adhesive for Autoclaved Aerated Concrete Block

Uses:

RAK BLOCK FIX can be used for laying
internal and external AAC (Autoclaved
Aerated Concrete) blocks and panels.

Mixing:

To prepare the mixture, pour in a container
10 to 10.5 Liters of clean water. Add a bag
of 50 Kg of RAK BLOCK FIX, then mix to get
a homogeneous lump free consistency
mix.
Let the product rests for about 5 minutes
and remix shortly before use.

Consumption:
4 – 5 kg/ m²

Ordering Guide:

PRODUCT NO. -- 112
PACKAGING -- 25 kg / 50 kg Bags
COLOR -- White / Grey

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select Link to start with 

1. 112 - RAK BLOCK FIX is a powder adhesive composed of hydraulic binders, bonding agents, quartz, synthetic resins and special additives formulated to obtain, when mixed with water, optimal characteristics of workability and high adhesion power to the support. It contains neither asbestos fibre nor other materials considered harmful for health of the applicator. • Factory controlled pre-blend ensures consistent high quality • Requires only addition of water on site at the time of usage • Strong adhesion to AAC Blocks • Mineral based non-hazardous Adhesive for Autoclaved Aerated Concrete Block 112 - RAK BLOCK FIX - LW ADVANTAGES 4 – 5 kg/ m² CONSUMPTION Tools and equipment should be cleaned with water immediately after use. Hardened materials should be mechanically removed. CLEANING • If the blocks are laid directly on a floor with possible humidity rising, it is recommended to apply a proper damp course system first • The 2 cm separation between the top of the block wall and the bottom of slab or beam should be filled with suitable compressible material • Spray the block wall with water before applying the plaster. • Ensure that the first layer of blocks is fixed proper with perfect alignment • Do not apply RAK BLOCK FIX in rainy weather, high winds and sand storms • Do not apply on surface that has temperature less than +5ºC • During summer season, working area should be covered to prevent the direct sun eects. Keep equipment cool and use a cool water • The product should not be exposed to moving water during application RECOMMENDATIONS RAK BLOCK FIX can be used for laying internal and external AAC (Autoclaved Aerated Concrete) blocks and panels. USES TECHNICAL PROPERTIES Properties Result Appearance Color Density at 25°C VOC Compressive Strength at 28 days (ASTM C579) Flexural Strength at 7 days (ASTM 580) Recommended thickness Noxiousity according to EEC 88/379 All values are subject to 5-10 % tolerance Powder grey, white 1.5 kg/L 3.3g/L 15.0 N / mm2 5.0 N / mm2 3 mm None To prepare the mixture, pour in a container 10 to 10.5 Liters of clean water. Add a bag of 50 Kg of RAK BLOCK FIX, then mix to get a homogeneous lump free consistency mix. Let the product rests for about 5 minutes and remix shortly before use. MIXING Saturate the block surface with water before applying the adhesive mortar any excess water should be removed. Place the first line of blocks on concrete slab using a traditional cement mortar. Apply RAK BLOCK FIX with special toothed trowel and then position the blocks verifying their alignment. Remove possible excess of mortar before it hardens. Ensure that the adhesive spread on the blocks has not formed a superficial film. In this case apply fresh mix with the toothed trowel. RAK BLOCK FIX should be applied in a thin layer to enable the continuity of thermo-insulation of the blocks. Leave a space of about 2 cm between the top of block wall and the bottom of slab or beam in order to avoid formation of cracks along the wall. This cavity should be filled with compressible material (see relative technical data sheets). After 24 hours of fixing the block wall, plastering may start using an appropriate plastering product such as RAK PLASTER 200 APPLICATION RAK BLOCK FIX is a cement-based product. During application, wear appropriate protective clothing, goggles, gloves and respiratory equipment if necessary. In case of contact with skin, rinse with water and again wash thoroughly with soap and water. In case of contact with eyes, rinse with plenty of water and seek medical advice accordingly. If ingested, obtain medical attention immediately. Do not induce vomiting. HEALTH & SAFETY ORDERING GUIDE 112 25 kg / 50 kg Bags White / Grey PRODUCT NO. PACKAGING COLOR RAK BLOCK FIX-LW 112 (Adhesive for Autoclaved Aerated Concrete Block) F L O O RIN G & TI L IN G W A T E R P R O O FIN G B ON D IN G A G E N T S S E ALA N T S & MO R T A R S S P E CIA L I T Y P R O DU C T S 10 TECHNICAL DATA SHEET

Views

  • 2449 Total Views
  • 1851 Website Views
  • 598 Embeded Views

Actions

  • 0 Social Shares
  • 1
  • 0
  • 0 Comments

Share count

  • 0  Facebook
  • 0  Twitter
  • 0  LinkedIn

Embeds 4

  • 77 www.sab-us.com
  • 16 161.97.92.48
  • 2 www.google.com
  • 4 161.97.92.48:8011

Website Visitors - 507764